PicoProbe™ Triglyceride (TG) Fluorometric Assay Kit

The most sensitive kit on the market
Catalog #: K614

In stock

$465.00

Product Details

Cat # +Size K614-100
Size 100 assays
Detection Method Fluorescence (Ex/Em 535/587 nm)
Applications Measurement of triglycerides in various tissues, cells & other biological fluids. Analysis of lipid metabolism. Mechanistic study of cardiovascular disease.
Features & Benefits • Simple, sensitive, easy to use, and high-throughput adaptable.
• Kit contains all necessary reagents for accurate measurement of triclyceride levels.
• This kit can detect less than 0.4 µM triglycerides in a variety of samples.
Kit Components • Triglyceride Assay Buffer
• PicoProbe™ (in DMSO)
• Lipase (lyophilized)
• Triglyceride Enzyme Mix (lyophilized)
• Triglyceride Developer (lyophilized)
• Triglyceride Standard (1 mM)
Storage Conditions -20°C
Shipping Conditions Gel Pack
USAGE For Research Use Only! Not For Use in Humans.

Details

Triglycerides (TG) are the main constituents of vegetable oil, animal fat, LDL and VLDL, and play an important role as transporters of fatty acids as well as an energy source. TG is broken down into fatty acids and glycerol, after which both can serve as substrates for energy producing and metabolic pathways. High blood levels of TG are implicated in atherosclerosis, heart disease and stroke as well as in pancreatitis. Biovision’s PicoProbe™ Triglyceride Assay kit is suitable for measuring triglyceride levels in samples, which contain reducing substances that may interfere with oxidase-based assays. In this assay, TG is hydrolyzed to glycerol and fatty acid. The glycerol reacts with Triglyceride Enzyme Mix to form an intermediate product, which in turn reacts with PicoProbe & Developer to generate the fluorescence. The generated fluorescence is directly proportional to the amount of triglycerides. This high-throughput adaptable assay kit is simple, sensitive and easy to use & can detect less than 0.4 µM triglycerides in a variety of samples.


Why buy BioVision Products?
Innovation
Affordability
Global Presence
Technical Support
BioVision aims to provide our customers innovative tools for accelerating drug discovery and biological research. BioVision offers >8,000 products including the most comprehensive array of assay kits for key targets in Metabolic pathways.
BioVision is committed to providing the highest quality products at a competitive price.
We have a broad network of global distributors who are ready to address your research needs and ensure fast delivery.
Our highly trained Technical Support team provides comprehensive product support and is dedicated to resolving your issues quickly and efficiently.
What is the difference between K614 and K622 (Triglyceride colorimetric/fluorometric assay kit)?
The picoprobe allows K614 to be manifold more sensitive than the K622. K614 detects triglycerides <0.4uM. K622 can detect 2uM-10mM triglycerides.
The values of the std curve are in the low hundreds. Why?
It is important to warm up the probe to >20C and the assay bufefr to RT to ensure that the reaction proceeds according to the normal time of incubation. Incompletely thawed or cold reagents can lead to a slow reaction and low values.
Can this asay be used for a HTS?
Yes, this assay is HTS adaptable.
Is deproteinizing recommended for all samples?
Deproteinization is not required for this assay.
What can cause background in this assay?
Glycerol and NADH are the primary sources of background in this assay. Substraction of background will help correct for this contribution. BSA (1% or higher) and PMSF might also interfere with the assay.
Will di- and mono- acyl glycerols be detected by this assay?
The Lipase enzyme that hydrolyzes TG is specific for only Triacylglycerol and thus di- and mono-glycerides will not be recognized in this assay.
Can tissue be stored in PBS-glycerol and then used to homogenize for the assay?
Glycerol creates background and hence tissu/cell storage in glycerol must be avoided, or the glycerol will need to be washed off before homogenization.
How are samples normalized against protein concentration?
A protein quantitation assay can be used with the supernatants from cell/tissue lysates or with any other liquid sample in the assay buffer.
Are trial sizes of this kit available?
Unfortunately, we do not have trial sizes of this kit available. However,for customers based in the US or Canada, a 10% off list price introductory discount can be offered on the list price. For all other customers based out of this area our regional BioVision distributor should be contacted
Can individual components of this kit be purchased separately?
Yes, any of the kit's components can be purchased separately without having to buy the whole kit. Please refer to the component Cat #s mentioned on the datasheet for ordering.
Can alternate buffers be used for sample preparation (cell lysis, sample dilutions etc)?
Our assay buffers are optimized for the reactions they are designed for. They not only contain some detergents for efficient lysis of your cells/tissue, but also contain some proprietary components required for the further reactions. Therefore, we highly recommend using the buffers provided in the kit for the best results.